RESIDENTIAL MEMBRANE ELEMENT

PLATINUM BW SERIES
Pacific residential reverse osmosis membrane series can effectively remove all kinds of impurities and pollutants in water, such as organics, microorganisms, heavy metal ions, etc. It is widely applied in residential water filters, commercial water filters, compact water vending machines, etc. It is large in output water flow, high in salt rejection, and stable in performance. What’s more, with strong research and development ability, Pacific is able to customize all kinds of reverse osmosis membranes for various purposes. Pacific membrane can be customized as per different applications and requirements of supply.
Model | Average Salt Rejection(%) | Minimum Salt Rejection(%) | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
BW-1812-075 | 98.5 | 97 | 13 to 15 LPH | 0.54 |
BW-2012-080 | 98.5 | 97 | 16 to 18 LPH | 0.68 |
BW-2012-100 | 98.5 | 97 | 18 to 20 LPH | 0.80 |
BW-2012-150 | 98.5 | 97 | 22 to 24 LPH | 0.88 |
BW-2012-300 | 98.5 | 97 | 45 to 50 LPH | 1.70 |
Testing Conditions:
- Testing Pressure: 90 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 2000 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 20%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0
LP SERIES

Model | Average Salt Rejection(%) | Minimum Salt Rejection(%) | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
LP-1812-75 | 98 | 96 | 13 to 15 LPH | 0.54 |
LP-2012-80 | 98 | 96 | 16 to 18 LPH | 0.68 |
LP-2012-100 | 98 | 96 | 20 to 22 LPH | 0.80 |
LP-2012-150 | 98 | 96 | 24 to 26 LPH | 0.88 |
LP-2012-300 | 98 | 96 | 45 to 50 LPH | 1.70 |
Testing Conditions:
- Testing Pressure: 75 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 500 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 25–30%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0
SILVER ULP SERIES

Model | Average Salt Rejection(%) | Minimum Salt Rejection(%) | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
ULP-1812-75 | 97.5 | 95 | 15 to 17 LPH | 0.54 |
ULP-2012-80 | 97.5 | 95 | 18 to 20 LPH | 0.68 |
ULP-2012-100 | 97.5 | 95 | 22 to 24 LPH | 0.80 |
ULP-2012-150 | 97.5 | 95 | 25 to 27 LPH | 0.88 |
ULP-2012-300 | 97.5 | 95 | 50 to 55 LPH | 1.70 |
Testing Conditions:
- Testing Pressure: 80 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 1500 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 25–30%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0
XLP SERIES

Model | Average Salt Rejection(%) | Minimum Salt Rejection(%) | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
XLP-1812-75 | 96 | 94 | 13 to 15 LPH | 0.54 |
XLP-2012-80 | 96 | 94 | 16 to 18 LPH | 0.68 |
XLP-2012-100 | 96 | 94 | 20 to 22 LPH | 0.80 |
XLP-2012-150 | 96 | 94 | 24 to 26 LPH | 0.88 |
XLP-2012-300 | 96 | 94 | 45 to 50 LPH | 1.70 |
Testing Conditions:
- Testing Pressure: 75 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 500 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 25–30%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0
XLP HIGH FLOW SERIES

Model | Average Salt Rejection(%) | Minimum Salt Rejection(%) | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
XLPHF-1812-75 | 94 | 90 | 13 to 15 LPH | 0.54 |
XLPHF-2012-80 | 94 | 90 | 16 to 18 LPH | 0.68 |
XLPHF-2012-100 | 94 | 90 | 20 to 22 LPH | 0.80 |
XLPHF-2012-150 | 94 | 90 | 24 to 26 LPH | 0.88 |
XLPHF-2012-300 | 98 | 90 | 45 to 50 LPH | 1.70 |
Testing Conditions:
- Testing Pressure: 75 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 500 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 25–30%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0
NF SERIES
RESIDENTIAL NANO FILTRATION MEMBRANE SERIES
Pacific residential nano filtration membrane has high water output and stable performance, which is specialized in removing dissolved organic carbon and softening water meanwhile. It selectively allows certain LMW and low-valent ions to pass through. It can effectively remove nitrate, pesticide, herbicide, household chemicals, bacteria, viruses. Meanwhile, it remains part of Na⁺, K⁺, Ca²⁺ in water, so that its output water has good test. On the other side, its output flow rate is high with low operating pressure. Sometimes it doesn’t need a pump, which can effectively reduce the cost and compress size of a direct drinking system.
Pacific residential nano filtration membrane has high water output and stable performance, which is specialized in removing dissolved organic carbon and softening water meanwhile. It selectively allows certain LMW and low-valent ions to pass through. It can effectively remove nitrate, pesticide, herbicide, household chemicals, bacteria, viruses. Meanwhile, it remains part of Na⁺, K⁺, Ca²⁺ in water, so that its output water has good test. On the other side, its output flow rate is high with low operating pressure. Sometimes it doesn’t need a pump, which can effectively reduce the cost and compress size of a direct drinking system.

SPECIFICATION AND MAIN PERFORMANCE OF MEMBRANE ELEMENTS
Model | Average Salt Rejection(%) | Suitable for Tap Water TDS | Average Permeated Flow(LPH) | Active Membrane Area (SQM) |
---|---|---|---|---|
NF-20-2012-100 | 20–30 | 250 PPM | 25 to 30 LPH | 0.68 |
NF-40-2012-100 | 40–50 | 400 PPM | 24 to 28 LPH | 0.68 |
NF-60-2012-100 | 60–70 | 600 PPM | 22 to 25 LPH | 0.68 |
NF-80-2012-100 | 80–85 | 800 PPM | 20 to 23 LPH | 0.68 |
Testing Conditions:
- Testing Pressure: 85 psi
- Temperature of Testing Solution: 27°C
- Concentration of Testing Solution: 250 ppm
- pH Value of Testing Solution: 8.0
- Recovery Rate: 25–30%
Operation Limits and Conditions:
- Max. Working Pressure: 150 psi
- Max. Working Feed Water Flow: 2 gpm
- Max. Feed Water Temperature: 45°C
- Max. Pressure SDI: 5
- Residual Chlorine Decline: < 0.1 ppm
- pH Range of Feed Water: 3.0–10.0